Quantity
|
Out of stock
|
||
|
|
|||
|
Notes on operation |
Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500.... |
|
Notes on operation |
The PLC-ATP separating plate should be installed for safe isolation between adjacent modules |
|
Assembly note |
The PLC-ATP separating plate is required at the start and end of every PLC terminal strip. |
|
Notes on operation |
The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact. |
Product properties
|
Product type |
Relay Module |
|
Product family |
PLC-INTERFACE |
|
Application |
Universal |
|
Operating mode |
100% operating factor |
|
Mechanical service life |
2x 107 cycles |
|
Data management status |
|
|
Date of last data management |
08.07.2024 |
|
Article revision |
01 |
|
Insulation characteristics |
|
|
Insulation |
Safe isolation, reinforced insulation |
|
Overvoltage category |
III |
|
Pollution degree |
3 |
Electrical properties
|
Maximum power dissipation for nominal condition |
0.22 W |
|
Test voltage (Winding/contact) |
4 kVrms (50 Hz, 1 min., winding/contact) |
|
Rated insulation voltage |
250 V AC |
|
Rated surge voltage |
6 kV |
Input data
|
Coil side |
|
|
Nominal input voltage UN |
5 V DC |
|
Input voltage range |
4.2 V DC ... 7 V DC (20 °C) |
|
Nominal voltage (plugged-in electromechanical relay) |
5 V DC |
|
Drive and function |
monostable |
|
Drive (polarity) |
polarized |
|
Typical input current at UN |
38 mA |
|
Typical response time |
5 ms |
|
Typical release time |
8 ms |
|
Protective circuit |
Reverse polarity protection; Polarity protection diode |
|
Surge protection; Freewheeling diode |
|
|
Operating voltage display |
Yellow LED |
Output data
|
Switching |
|
|
Contact switching type |
1 changeover contact |
|
Type of switch contact |
Single contact |
|
Contact connection type |
Power contact |
|
Contact material |
AgSnO |
|
Maximum switching voltage |
250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
|
Minimum switching voltage |
5 V (100 mA) |
|
Limiting continuous current |
6 A |
|
Maximum inrush current |
10 A (4 s) |
|
Min. switching current |
10 mA (12 V) |
|
Short-circuit current |
200 A (conditional short-circuit current) |
|
Interrupting rating (ohmic load) max. |
140 W (at 24 V DC) |
|
20 W (at 48 V DC) |
|
|
18 W (at 60 V DC) |
|
|
23 W (at 110 V DC) |
|
|
40 W (at 220 V DC) |
|
|
1500 VA (for 250 V AC) |
|
|
Output fuse |
4 A gL/gG NEOZED |
|
Switching capacity |
2 A (at 24 V, DC13) |
|
0.2 A (at 110 V, DC13) |
|
|
0.1 A (at 220 V, DC13) |
|
|
3 A (at 24 V, AC15) |
|
|
3 A (at 120 V, AC15) |
|
|
3 A (at 230 V, AC15) |
|
Connection data
|
Connection method |
Push-in connection |
|
Stripping length |
10 mm |
|
Conductor cross section rigid |
0.14 mm² ... 2.5 mm² |
|
Conductor cross section flexible |
0.14 mm² ... 2.5 mm² |
|
0.2 mm² ... 2.5 mm² (Single ferrule) |
|
|
2x 0.5 mm² ... 1 mm² (TWIN ferrule) |
|
|
Conductor cross section AWG |
26 ... 14 |
Dimensions
|
Width |
6.2 mm |
|
Height |
80 mm |
|
Depth |
94 mm |
Material specifications
|
Color |
gray (RAL 7042) |
|
Flammability rating according to UL 94 |
V0 (Housing) |
Environmental and real-life conditions
|
Ambient conditions |
|
|
Degree of protection (Relay) |
RT III (Relay) |
|
Degree of protection (Relay base) |
IP20 (Relay base) |
|
Degree of protection (Installation location) |
IP54 (Installation location) |
|
Ambient temperature (operation) |
-40 °C ... 60 °C |
|
Ambient temperature (storage/transport) |
-40 °C ... 85 °C |
|
Altitude |
≤ 2000 m |